Flameout
The FADEC activates the igniters when there is a flameout inflight or on the ground. A FAIL amber annunciation appears on the MFD over the N1, and a WML annunciation over the N2 indicates an auto-relight is in progress. The ignition remains on for 5s after the flameout detection has been cleared.