Hydraulic Logic


Auto mode (Sys 1 & 2)

  • ON when
    • EDP fail
    • Eng fail
    • flaps > 0 (not zero)
  • for 60 seconds on TKOF / LDG
  • ground ops ON when
    • flaps > 0
    • TOGA & GS > 50 kts

Auto mode sys 2 only

  • on ground
    • Eng 1 running & Brakes released
    • Eng 1 running & Flaps > 0
    • During Eng 1 start if Brakes applied 6 min before