Powered by 28V DC from SPDA 1 DC Bus 1. There is no backup power to this system. The system starts in OFF mode. With one controller OFF and the other in an operating mode, the system is in slave mode, where the operating controller controls both sweeps. The normal sweep is 12 per minute and 60° either side of heading.


Virtual controller

TURBonly in WX mode at ranges 50nm or less
GAINcalibrated is selected when TGT or RCT are selected, otherwise can select VAR (variable gain)
TGTmonitors for red or magenta beyond selected range
SECTchanges sweep to 24 per minute and 30° either side of heading
ACTaltitude compensated tilt
RCTauto adjust sensitivity due to attentuation through targets
LXlightning sensor on or off