• article
  • [a330:integrated_drive_generato…]
  • home
  • left
  • right
  • backlinks
  • print
  • Bookmark and Share
  •  

Integrated Drive Generator

Also from: IDG


Converts variable engine speed to constant speed to drive the engine driven generators. The IDG rise indication is the difference between IDG oil inlet and outlet temperature. If disconnected the IDGs can only be connected again on the ground.


Failures

High oil temperature or low oil pressure in an IDG could cause damage to the accessory gearbox of the engine, and so must be disconnected.


ELEC IDG 1(2) OIL LO PR- the IDG will have to be disconnected
- press the IDG pb sw until the FAULT light comes on, but not more than 3s to avoid damage to the disengage solenoid
- a DISC is shown on the ELEC AC page

Categories: Airbus A330 | Electrical System