Ice and Rain Protection


Includes these subsystems:


The wing and engine anti-ice systems remain active for 5 minutes after they have been automatically activated and icing conditions no longer exist.


Water and waste

The forward and rear drain masts are heated to prevent ice formation during draining, and the water fill nipple is heated to prevent ice formation during filling.


Door sills

The door sills are also automatically heated to prevent snow accumulation at the doors. They operate with WOW, the doors open, and OAT <4.4°C. The power source is 115VAC, single-phase. A failure generates a message on the CMC.