Alpha Floor

Also from: α Floor


Alpha Floor is triggered by the FMGCs upon a signal from the PRIMs when:

  • angle of attack exceeds a pre-determined threshold (as a function of configuration).

The A/THR activates (regardless of status or thrust lever position) when Alpha Floor is activated.


Inhibits

  • engine failure with flaps extended(1)
  • engine failure with derated T/O selected
  • below 100' RA at landing
  • above M.53

Failures

Alpha Floor protection is lost in case of A/THR failure.


Notes

(1): With one engine TLA below 5° and the other above 5°, the system may consider the engine to be failed


Categories: Airbus A330 | Auto Flight | Flight Guidance | Auto Thrust