Engine Interface Unit

Also from: EIU; EIVMU


The EIU interfaces with the FADEC.


The EIU inputs are:

  • engine start and manual start switches
  • zone controller, for bleed demand
  • LGCIU
  • SFCC
  • A/THR

Failures

As bleed demand is unknown to FADEC, idle speed is increased to approach idle. A/THR is not available. Manual starts are not available. Thrust reverse is lost.